水力发电学报
            首 页   |   期刊介绍   |   编委会   |   投稿须知   |   下载中心   |   联系我们   |   学术规范   |   编辑部公告   |   English

水力发电学报 ›› 2026, Vol. 45 ›› Issue (9): 39-49.doi: 10.11660/slfdxb.20260904

• • 上一篇    下一篇

调压室参数对抽蓄电站引水上平段最小压力的影响

  

  • 出版日期:2026-09-25 发布日期:2026-09-25

Effect of surge chamber’s parameters on minimum pressure along upper flat pipe segment in pumped-storage power stations

  • Online:2026-09-25 Published:2026-09-25

摘要: 抽水蓄能电站引水上平段最小压力是保证引水系统管道安全和机组运行稳定的重要控制参数。建立融合Sobol全局灵敏度分析的抽水蓄能电站输水发电系统瞬变流分析模型,系统探究是否设置引水调压室,引水调压室流进/流出流量系数、阻抗孔直径和调压室直径对引水上平段控制断面最小压力的影响,并通过Sobol方法对各参数敏感性进行定量分析。研究表明:考虑设置引水调压室,合理优化提升流进/流出流量系数、适当增大阻抗孔直径和调压室直径有利于改善引水上平段最小内水压力,流量变化率是影响引水上平段最小压力的重要因素之一,定量揭示了参数变化对最小压力的独立影响和参数间的交互效应,其中最小压力受阻抗孔直径影响较大,调压室直径和流进/流出流量系数次之,研究成果为引水管道布置参数的定量评估和优化设计提供重要技术支撑。

关键词: 抽水蓄能电站, 水力过渡过程, 引水上平段, 引水调压室

Abstract: The minimum pressure head along the upper flat pipe section is recognized as a critical control parameter for ensuring hydraulic safety and operational stability in pumped-storage power stations. A mathematical model for transient flow analysis in the water conveyance system is developed, and a Sobol-based global sensitivity analysis method is incorporated. The influences of upstream surge chamber installation, along with three key design parameters—the inflow-outflow coefficient, throttled orifice diameter, and surge chamber diameter—on the minimum pressure at two selected control cross sections are systematically investigated. The minimum internal pressure at these sections is found to be effectively improved by the provision of an upstream surge chamber, by the optimization of the inflow-outflow coefficient, and by the increase of both the throttled orifice diameter and the surge chamber diameter. Among all influencing factors, the flow variation rate is identified as the dominant variable affecting the minimum pressure at the two sections. By means of the Sobol method, not only the individual effects of each parameter but also their pairwise interaction effects on the minimum pressure are quantitatively evaluated. The sensitivity indices are calculated, and the throttled orifice diameter is shown to exert the most significant influence, followed by the surge chamber diameter and the inflow-outflow coefficient, in descending order. Technical support for the evaluation and optimization of pipeline layout parameters in similar hydraulic systems is provided by the obtained results.

Key words: pumped-storage power station, hydraulic transition, minimum pressure at the upper flat pipe segment, upstream surge chamber