Abstract: Six field experimental devices have been used to study the performance of bioretention tanks with different fillers in purification of urban road runoff. Through field tests, mathematical statistics and numerical simulation, this study focused on the control effect of bioretention tanks under the influences of five major factors: filler types, filler combinations, filler thickness, pollutant characteristics, and vegetation conditions. Multi-level orthogonal tests on these factors show that the best way to remove pollutants is to select fly ash for the filler and a filter thickness of 45cm, along with the vegetation of boxwood combined with Ophiopogon japonicus. We developed multiple regression models of removal rate of the pollutants (total nitrogen and total phosphorus) versus the influencing factors. Our simulation of the migration of TP in the tanks in three inflow concentration scenarios using Hydrus-1D achieved satisfactory results of mean relative errors 16.51%, 13.03%, and 23.49% relative to the measured values.
李鹏,李家科,林培娟,邓朝显,黄宁俊,马越. 生物滞留槽对城市路面径流水质处理效果的试验研究[J]. 水力发电学报, 2016, 35(8): 72-79.
LI Peng, LI Jiake, LIN Peijuan, DENG Zhaoxian, HUANG Ningjun, MA Yue. Experimental study on effects of bioretention tank purifying urban road runoff[J]. JOURNAL OF HYDROELECTRIC ENGINEERING, 2016, 35(8): 72-79.