JOURNAL OF HYDROELECTRIC ENGINEERING ›› 2015, Vol. 34 ›› Issue (2): 144-148.
Previous Articles Next Articles
Online:
Published:
Abstract: Compared with the concrete liner pre-stressed with circumferential bonded tendons, the tunnel liner pre-stressed with circumferential un-bonded tendons has many outstanding advantages, but the reliability restrict its general application. Stress state variation of tendon is one of the important parameters to evaluate the reliability of this type of liner structure. Based on the long-term monitoring data of tendon dynamometers in Xiao Langdi pre-stressed sediment tunnels, the influences of ambient temperature and water head on the tendon stress were analyzed. The results show that the variation of temperature has a significant effect to the tendon stress, while the variation of water head has a little impact. Xiao Langdi pre-stressed sediment tunnels has been safely served for more than 10 years and experienced the highest design water head, the prestress in the tendons is stable at all times, no fracture or relaxation of un-bonded steel strands was observed. The experience of Xiao Langdi sediment tunnels shows that the anchorage of un-bonded tendons is reliable and a safe operation can be realized for the tunnel concrete liner pre-stressed with circumferential un-bonded tendons.
WANG Xiaozhe, KANG Jingfu, et al. Reliability analysis of the tunnel liner pre-stressed with circumferential un-bonded tendons based on the monitoring data[J].JOURNAL OF HYDROELECTRIC ENGINEERING, 2015, 34(2): 144-148.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://www.slfdxb.cn/EN/
http://www.slfdxb.cn/EN/Y2015/V34/I2/144