摘要: 西南地区高混凝土重力坝受复杂温度边界及运行环境影响,坝体内部温度分布和运行期应力状态难以直接获取。以景洪重力坝17坝段为对象,基于温度监测、库水位及垂线位移资料,建立坝体—地基二维有限元模型,拟合上下游坝面温度边界,开展运行期温度场计算,并结合位移监测结果对坝体混凝土弹性模量进行参数反演,在此基础上进行运行期应力仿真分析。结果表明:坝前库水温沿高程呈明显分层分布,上游坝面温度主要受库水影响,坝体内部温度场整体较稳定;坝段上下游向水平位移与气温变化一致性较好,与水位相关性不明显;坝体整体以受压为主,低温条件下上游坝面水位以上局部区域出现小范围拉应力。分析表明,17坝段运行期整体工作状态稳定,温度作用是影响坝段位移与局部应力分布的重要因素。

关键词: 重力坝, 有限元分析, 温度场计算, 参数反演, 运行期应力计算

Abstract: Under the conditions of complicated temperature boundaries and operating environments of a high concrete gravity dam in Southwest China, it is usually difficult to directly measure its internal temperature distribution and long-term stress state. In this study, we develop a two-dimensional finite element model of the dam?foundation system, based on monitored temperature data, reservoir water level records, and plumb line displacements, and tested in a case study of Monolith 17 of the Jinghong gravity dam. The operating temperature field is calculated through fitting temperature boundary conditions at the upstream and downstream dam surfaces, and validated using the monitored internal temperatures of the dam. And, we calibrate the elastic modulus of dam concrete using a back-analysis of the displacement measurements. On this basis, the stress distribution during operation is numerically simulated. The results show that reservoir water temperature in front of the dam exhibits obvious stratification along the same elevation; Upstream face temperature is mainly controlled by reservoir water, and the internal temperature field of the dam is generally stable. The calculated horizontal displacement of the monolith in the streamwise direction agrees well with variations in air temperature, but shows no obvious correlation with the reservoir stage. We also find that the majority of the dam concrete is in compression, while under low-temperature conditions, small tensile stress zones appear locally in the upstream dam face layer above the water level. It is revealed that Monolith 17 is in a stable working state during operation, and thermal action is a key factor affecting the deformation and local stress distributions of the monolith.

Key words: gravity dam, finite element analysis, temperature field calculation, parameter back-analysis, stress calculation