Abstract: Influences of soft foundation on the dynamic response of hydropower house and methods of dynamic loads application are investigated using FEM simulation, focusing on a detailed analysis of the composition, amplitude and frequency of dynamic loads on the generator units. Results show that more attention must be paid to the impact of foundation boundary conditions in the case of a significant difference in stiffness between the house structure and its foundation. And the simulated vibrations are closer to the real cases if the loads are applied according to frequency differences. Coupling effects between generator pier vibrations in different directions have been observed.
SONG Zhiqiang, ZHAO Enhong. Analysis on endogenous vibrations of hydropower house on soft foundation[J].JOURNAL OF HYDROELECTRIC ENGINEERING, 2014, 33(6): 181-186.